Radwag HY10.300.1.HRP.M3 High Resolution Scale

OVERVIEW

Maximum capacity [Max]: 100 / 200 / 300kg

Readability [d]: 10 / 20 / 50g
The Most Precise Weighing Results in Industrial Conditions
Advanced HY10.HRP.H multifunctional scale enables fast and precise mass measurements in challenging industrial conditions. The scale enables carrying out measurements with very high resolutions available so far only for laboratory balances.
 
Reliability and Safety
Robust platform made of stainless steel and high ingress protection allow to operate the scale in moist environment and at direct contact with water (e.g. meat and fish industry, etc.). The protection system against overloads and mechanical shocks ensures durability and endurance in everyday use.
 
Versatility of Use
HY10.HRP.H scale is perfect for applications requiring high accuracy, precision and repeatability of measurement in challenging industrial conditions.
Cooperation with PUE HY10 Indicator
The scale can be operated via advanced PUE HY10 indicator 
controlled by Linux system. Hermetic housing is made of stainless steel.
Uncomplicated Operation and Clear Presentation of Indications
10.1” large colour touch screen ensures excellent readability and comfortable operation. Clear menu and intuitive information arrangement on the display guarantee user-friendly performance.
Automatic Adjustment
Internal adjustment system guarantees the highest accuracy and reliable measurements results.
Uncomplicated Databases Archiving
An extensive database enables archiving work results and periodic reports, data exchange between indicators and information import and export. Images database allows to assign a graphic to each weighing product.


 

Butuh Bantuan?

Informasi Produk

FUNCTIONS

DOSING

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph – load indicator. For industrial scales it is possible to use a control systems of dosing process.

LABELLING

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).

PLUS/MINUS CONTROL

Control of sample’s mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.

PERCENT WEIGHING

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.

TOTALIZING

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.

PARTS COUNTING

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.

PEAK HOLD

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.

FORMULATION

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.

STATISTICS

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.

CHECKWEIGHING

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961

GLP PROCEDURES

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.

ANIMAL WEIGHING

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.

DIFFERENTIAL WEIGHING

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.

REPLACEABLE UNIT

Replaceable units.

STATISTICAL QUALITY CONTROL

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.

ALIBI MEMORY

“ALIBI” memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.

The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.

The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.

Measurements saved to balance memory cannot be deleted.

You can preview and print out the data saved to the ALIBI database.

TRANSACTIONS

Complex weighing mode for registration of weighings that are part of transactions such as sale, purchase and warehouse transfer. You can create a new transaction using the scale. It is possible to pause the transaction or abort it.  The function supports warehouse management in an enterprise.

DATASHEET

Maximum capacity [Max]100 / 200 / 300 kg
Minimum load200 / 400 / 1000 g
Preload range60 kg
Readability [d]10 / 20 / 50 g
Tare range-300 kg
Verification scale interval10 / 20 / 50 g
Maximum quantity of verification units10000 / 10000 / 6000 e
Repeatability3 g
Linearity±6 g
Stabilization time3 s
Adjustmentinternal (automatic)
OIML ClassIII
Display10.1” graphic colour touchscreen
Protection classIP 66/67 construction, IP 68/69 indicator
USB×2
Ethernet×1
RS232×2
Inputs/Outputs4IN / 4OUT
Power supply100 ÷ 240 V AC 50 / 60 Hz
Operating temperature+10 ÷ +40 °C
Relative humidity40% ÷ 80%
Weighing pan dimensions1000×800 mm
Net weight71.5 kg
Gross weight119 kg
ACCESSORIES
  • Audit Trail Reader
  • E2R System
  • Label Editor R02
  • Parameter Editor
  • Scales Editor 2.0
  • R.Barcode
  • R-LAB
  • RAD-KEY
  • RADWAG Connect
  • RADWAG Development Studio
  • RADWAG Remote Desktop
  • labVIEW Driver
  • Receipt Printer
  • Label Printers
  • Moxa Uport 1110 Converter
  • RS 232 cables (scale – ZEBRA printer)
  • RS 232 cables (terminal – terminal)
  • IN/OUT Cables
  • RS 232 cables (scales – Ethernet)
  • RS 232 cables (scale- EPSON printer)
  • RS 232, RS 485 cables
  • USB cable (scale – printer)
  • Keypad, external switches
  • Barcode Scanners
  • Displays

ADDITIONAL MODULES

RDA (RADWAG Data Access)
RADWAG Data Access (RDA) module enables integration of weighing instruments, based on HY10 indicator, with customers’ IT systems. The module has to be unlocked with a license key (Setup/Misc./Extensions module/RDA data access module). The activation must proceed in accordance with the instructions displayed on the indicator. Communication is carried out via WebSocket and all data has to be sent as JavaScript Object Notation (JSON). Data can be sent from customer system to the weighing instrument (databases – products, customers, operators, etc.) and the other way around (reports – weighings).
Audit Trail
The Audit Trail registers each data modification (date, start value, modified value, operator responsible for the modification). This enables tracking all activities and modifying them in the future if required.
The Audit Trail Reader freeware enables to acquire data from the weighing instrument and export it as files to pdf, xls, csv, html formats.

Our customer support team is here to answer your questions. Ask us anything!
//
Jawa Barat
BAYU SOFYAN
Available
//
Jawa Timur & Jawa Tengah
MARYOTO
Available
//
Jakarta, Banten, Sumatra & Sulawesi
ABDUL SYUKUR
Available
NOTICE
We use cookies to make your experience of our websites better.