Radwag MA 200.3Y.WH Moisture Analyzer

OVERVIEW

Maximum capacity [Max]: 200g

Readability [d]: 1mg

Moisture analyzer is a laboratory measuring instrument intended to determine relative moisture content in samples of different substances. MA 3Y features 5,7″ LCD colour touch panel which provides new possibility within the scope of balance operation and presentation of measurement result. It features extended databases containing programmable drying modes related to the database of samples. The MA 3Y series enables printing and exporting charts presented on its display to a BMP file.

Customization of instrument’s settings is possible thanks to extended user profiles. The balance 
level is monitored by LevelSENSING system, RADWAG patented solution, which uses a system of an electronic level. Standard and user defined printouts allow for maintaining documentation complying with GLP/GMP requirements practically in any organization.

 


 

Butuh Bantuan?

Informasi Produk

FEATURES

Electronic level indicator

Functions:

  • ALARM function
  • graphic level indicator
  • programmable acceptable tilts

DATA EXCHANGE THROUGH USB STORAGE DEVICES

  • update balance software
  • export weighing data
  • export/import databases
  • export/import balance settings
  • exchange data between balances

INFRARED PROXIMITY SENSORS

Optional functions:

  • PRINT function
  • TARE function
  • sensor’s sensitivity adjustment

COMMUNICATION INTERFACES

  • Ethernet
  • 2×RS 232
  • 2×USB
  • additional display port

PORTABILITY

Application:

Elimination of extra sources of vibration
Using wireless terminal facilitates elimination of additional vibrations resulting from daily operation on a balance. Owing to that, balances with highest resolutions might be used without the need of dedicated weighing workstations.

Convenience and comfort of weighing in fume cupboards and laminar flow cabins
Wireless communication between a terminal and a weighing module makes balance operation more comfortable and safer.

Balance isolation form influence of environmental conditions
Wireless communication allows to either place the weighing module inside a draft shield or to isolate it from the operator. This allows to weight toxic substances without putting operator’s health or life at risk.

FUNCTIONS

DRYING MODES

Method for obtaining maximum drying temperature. There are 4 drying profiles: standard, mild, step, fast. The profiles differ by which ensure various dynamics of temperature increase.

SAMPLES DRYING

Drying process enables to determine moisture content of a given sample by evaporating its free water and other components. The sample’s moisture content [%M] is determined by means of precise weighing carried out before and during the drying process.

MOISTURE CONTENT ANALYSIS

Determination of sample’s moisture content.

DRY MASS DETERMINATION

Determination of product mass after completed technological, physical and chemical processes enforcing product moisture evaporation. RADWAG moisture analyzers are designed to test the moisture content by heating of the samples, which is done using an IR emitter, a halogen or a metal heater.
DATASHEET
Maximum capacity [Max] 200 g
Readability [d] 1 mg
Tare range -200 g
Adjustment external
Display 5.7” resistive colour touchscreen
Communication interface RS232, 2×USB, 4 IN / 4 OUT (digital), Ethernet, Wi-Fi®
Power supply 100 ÷ 240 V AC 50 / 60 Hz
Power consumption 8 W
Operating temperature +10 ÷ +40°C
Maximum sample weight 200 g
Heating module halogen
Heating module power 450 W
Moisture content repeatability +/-0.05% (sample ~ 2g), +/-0.01% (sample ~ 10g)
Moisture content readability 0.001%
Drying temperature range max 250°C
Drying method 4 drying profiles (standard, fast, step, mild)
Finish mode 4 modes (automatic, manual, time-defined, user-defined)
Maximum sample height 20 mm
Weighing pan dimensions ø90, h= 8 mm
Packaging dimensions 595×395×420 mm
Net weight 6 kg
Gross weight 10 kg
Additional functions sample traceability, drying graph

ACCESSORIES

  • Antivibration tables for industrial scales
  • E2R System
  • RAD-KEY
  • RADWAG Development Studio
  • RADWAG Remote Desktop
  • labVIEW Driver
  • Water Vapour Permeability Set
  • Moisture analyzer accessories
  • Receipt Printer
  • Label Printers
  • USB Hubs
  • RS 232, RS 485 Cables
  • Moxa Uport 1110 Converter
  • RS 232 cables (scale-EPSON Printer)
  • Protective Cover for Balances
  • Barcode Scanners

DRYING PARAMETERS

Drying Parameters for MAC and MAX

Drying Parameters for MA 3Y, MA X2 and MA R

  • Chemical industry
  • Fruit and vegetable
  • Bakery industry
  • Agricultural industry
  • Food industry
  • Plastics
  • Dairy products
  • Other

Drying Parameters for PMV

  • Dairy products

CAUTION
The analysis was carried out at customer request on selected models of moisture analyzers. RADWAG guarantees identical result of tests carried out on all versions of moisture analyzers.

Tim support kami siap menjawab pertanyaan Anda. Tanyakan apa saja kepada kami!
//
Jawa Barat
BAYU SOFYAN
Available
//
Jawa Timur & Jawa Tengah
MARYOTO
Available
//
Jakarta, Banten, Sumatra & Sulawesi
ABDUL SYUKUR
Available