Radwag PM 35.4Y Precision Balance

OVERVIEW

Maximum capacity [Max]: 35kg

Readability [d]: 0.1g

PM series balances are equipped with an innovative measuring system based on RADWAG MonoBLOCK® technology. This enables operation with readability of 0.01g at capacity of 15kg, and with readability of 0.1g at capacity of 50 kg.

Use of the new measuring system, which is a subject matter of RADWAG patent, guarantees stability of repeatability over time at a range sd<1d. The unique measuring system solution is characterized with great resistance to ambient conditions change.
An in-built 4-point protection system prevents balance 
overloading, this ensures safety in case too heavy load is applied onto the weighing 
pan.
Main features:
  • new RADWAG MonoBLOCK® sensor;
  • unrivalled repeatability of indications;
  • weighing of heavy loads with maximum accuracy;
  • intuitive operation guaranteed by a colour touchscreen;
  • compliance with CFR21;
  • fast mass measurements;
  • robust mechanical design – new lower weighing platform;
  • improved ergonomics – two types of weighing terminal for selection.

Balance offers possibility of weighing loads outside the weighing platform (so called under-pan weighing). This is an alternative for weighing loads with non-standard dimensions and shapes or those generating magnetic field.


 

Butuh Bantuan?

Informasi Produk

FEATURES

ELECTRONIC LEVEL INDICATOR

Functions:

  • ALARM function
  • graphic level indicator
  • programmable acceptable tilts

DATA EXCHANGE THROUGH USB STORAGE DEVICES

  • update balance software
  • export weighing data
  • export/import databases
  • export/import balance settings
  • exchange data between balances

INFRARED PROXIMITY SENSORS

Optional functions:

  • PRINT function
  • TARE function
  • sensor’s sensitivity adjustment

FUNCTIONS

AUTOTEST

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.

DOSING

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph – load indicator. For industrial scales it is possible to use a control systems of dosing process.

PERCENT WEIGHING

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.

PARTS COUNTING

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.

FORMULATION

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.

STATISTICS

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.

CHECKWEIGHING

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961

IR SENSORS

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.

GLP PROCEDURES

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.

ANIMAL WEIGHING

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.

AIR DENSITY CORRECTION

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.

DIFFERENTIAL WEIGHING

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.

REPLACEABLE UNIT

Replaceable units.

STATISTICAL QUALITY CONTROL

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.

WI-FI®

Wi-Fi® offers possibility to send data from balance to a mobile iOS or Android device, via special data management apps. Wireless communication between the indicator and the weighing instrument enables operating the balance that is placed inside a laminar flow hood or a fume cupboard.

DATASHEET

Maximum capacity [Max]35 kg
Minimum load5 g
Preload range3.5 kg
Readability [d]0.1 g
Tare range-35 kg
Minimum weight (USP)82 g
Minimum weight (U=1%,k=2)8.2 g
Repeatability (Max)0.1 g
Repeatability (5% Max)0.04 g
Linearity±0.3 g
Stabilization time3 s
Adjustmentinternal (automatic)

 

Display5.7” resistive colour touchscreen
Communication interface2×RS232, 2×USB-A, Ethernet, Wi-Fi®
Power supply100 ÷ 240 V AC 50 / 60 Hz
Power consumption max.0.5 A
Operating temperature+10 ÷ +40°C
Weighing pan dimensions350×260 mm
Packaging dimensions520×520×280 mm
Net weight11 kg
Gross weight13.2 kg

ACCESSORIES

  • Granite Antivibration tables
  • Antivibration tables for laboratory balances
  • Antivibration tables for industrial scales
  • Audit trail reader
  • E2R System
  • Label Editor R02
  • Parameter Editor
  • R.Barcode
  • R-LAB
  • RAD-KEY
  • RADWAG Connect
  • RADWAG Development Studio
  • RADWAG Remote Desktop
  • labVIEW Driver
  • Receipt Printer
  • USB Hubs
  • RS 232, RS 485 Cables
  • Moxa Uport 1110 Converter
  • RS 232 cables (scale-EPSON Printer)
  • Protective Cover for Balances
  • Barcode Scanners
  • AP2-1 Current Loop Unit
  • Displays
  • Power Adapters

ADDITIONAL MODULES

21 CFR Part 11 Compliance Module

The 21 CFR Part 11 Compliance Module is a solution especially useful for those users who are obliged to conform to provisions of 21 CFR Part 11 and EU GMP Part 4, Annex 11 regulations. These two documents determine the rules for using electronic records and signatures.

Data protection is guaranteed by:

  • advanced password settings,
  • control of logging correctness, various permission levels,
  • data management access,
  • backup,
  • electronic signature,
  • time-defined automatic logout,
  • modification record to Audit Trail file.

The module features “Audit Trail” which registers each data modification (date, start value, modified value, operator responsible for the modification). This enables tracking all activities and modifying them in the future if required.
The Audit Trail Reader freeware allows users to acquire data from the weighing instrument and export it as files to pdf, xls, csv, html formats.

Our customer support team is here to answer your questions. Ask us anything!
//
Jakarta, Banten, Sumatra & Sulawesi
ABDUL SYUKUR
Available
//
Jawa Timur & Jawa Tengah
MARYOTO
Available
//
Jawa Barat
BAYU SOFYAN
Available
NOTICE
We use cookies to make your experience of our websites better.