Software functionality:
- available working modes: weighing, parts counting, percent setup, formulation, density determination, animal weighing;
- generating standard labels for single products;
- generating C labels for cumulative containers;
- generating CC labels for containers with cumulative containers;
- three methods of triggering a C and CC label printout:
- manually,
- by counter status,
- by set mass value of a product;
- control scale mode (+/- control of weighing result);
- product identification using EAN-13 and EAN-128 codes;
- access to databases of operators, products, raw materials, clients, weighing records, universal variables and tares.
WLY balance enables quick search for a product by means of a connected barcode scanner. This option considerably increases functionality of the system.
The indicator can integrate with a PC software, “LABEL EDITOR”, which software communicates with the weighing device either through RS 232 interface or through ETHERNET.
WLY series is available in dual range (non-verified) version on surcharge.
FEATURES
DATA EXCHANGE THROUGH USB STORAGE DEVICES
- update balance software
- export weighing data
- export/import databases
- export/import balance settings
- exchange data between balances
INFRARED PROXIMITY SENSORS
Optional functions:
- PRINT function
- TARE function
- sensor’s sensitivity adjustment
MODES
Standard scale has built in modes of “Parts counting” and “Checkweighing”.
INTERFACES
- Ethernet
- 2×USB
- 2×RS 232
- 4 in / 4 out
- WiFi 2,4GHz b,g,n
FUNCTIONS
DOSING
Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph – load indicator. For industrial scales it is possible to use a control systems of dosing process.
LABELLING
Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
PLUS/MINUS CONTROL
Control of sample’s mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.
PERCENT WEIGHING
Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly exceeded.
TOTALIZING
Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
PARTS COUNTING
Function using mass measurement for determination of measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
PEAK HOLD
Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
FORMULATION
Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
STATISTICS
Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
CHECKWEIGHING
Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR SENSORS
Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
ANIMAL WEIGHING
Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
DIFFERENTIAL WEIGHING
Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.
Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
ALIBI MEMORY
“ALIBI” memory enables saving and storing up to 100000 measurements. Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
DATASHEET
Maximum capacity [Max] | 30 kg |
Minimum load | – g |
Readability [d] | 0.5 g |
Tare range | -30 kg |
Verification scale interval | – g |
Repeatability | 1 g |
Linearity | ±1 g |
Stabilization time | 3 s |
Adjustment | external |
OIML Class | – |
Protection class | IP 43 |
Communication interface | 2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi® |
Power supply | 100 ÷ 240 V AC 50 / 60 Hz |
Operating temperature | +15 ÷ +30 °C |
Storage temperature | -25 – +70 °C |
Relative humidity | 10% ÷ 85% RH no condensation |
Weighing pan dimensions | 300×300 mm |
Packaging dimensions | 570×390×170 mm |
Net weight | 5.2 kg |
Gross weight | 6 kg |
ACCESSORIES
- F1 Mass Standard – knob weight without adjusment chamber, set
- Granite Antivibration tables
- Audit Trial Reader
- E2R System
- Label Editor R02
- Parameter Editor
- Scales Editor 2.0
- R.Barcode
- R-LAB
- RAD-KEY
- RADWAG Connect
- RADWAG Development Studio
- RADWAG Remote Desktop
- labVIEW Driver
- Receipt Printer
- Label Printers
- RS 232, RS 485 Cables
- RS 232 cables (scale-EPSON Printer)
- Moxa Uport 1110 Converter
- Cigarette lighter receptacle power supply cables
- AP2-1 Current Loop Unit
- IN/OUT Cables
- Keypad, external switches
- USB Hubs
- Barcode Scanners
- Stands, wall mounting kits and mounting brackets
- Displays
- Power Adapters
ADDITIONAL MODULES
The Audit Trail Reader freeware enables to acquire data from the weighing instrument and export it as files to pdf, xls, csv, html formats.