Radwag WPT 3/HR2 Waterproof Scale With Stainless Steel Load Cell

OVERVIEW

Maximum capacity [Max]: 3kg

Readability [d]: 1g

Application:
Waterproof platform scales WPT/HR series is designed for operation in locations with high humidity or direct contact with water. The scales is easily used in areas with no access to power supply from mains, as it features an internal rechargeable accumulator.
Design:
 
Single load cell stainless steel platform scales WPT HR series is based on an indicator PUE C/31H series. The indicator 
features large backlit LCD display and function buttons for easy operation. The indicator is installed on a pillar for easy readout of measurement result. Optionally, the scales is offered with indicator installed on a cable for mounting it on a wall.
 
The weighing platform structure is made of stainless steel class AISI 316 with a stainless steel load cell providing the highest IP rating of 68. The scales features RS 232 interface, and optionally an additional display socket. The scales is powered from mains or internal rechargeable accumulator. Optionally, the scales can be powered from mains – 110÷120VAC 60Hz (non-standard factory option).
Scales WPT/HR series is available in dual range (non-verified) version on surcharge.


 

Butuh Bantuan?

Informasi Produk

FUNCTIONS

PLUS/MINUS CONTROL

Control of sample’s mass carried out with reference to specified MIN and MAX thresholds. The weight is considered to be correct if it is comprised within threshold values. A graphic visualisation of weighing result is displayed in a form of a bar graph.

PERCENT WEIGHING

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.

TOTALIZING

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.

PARTS COUNTING

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.

INTERNAL BATTERY

Internal and rechargeable battery of SLA 6 V type (sealed lead acid) enables device operation without connecting the device to the mains (9h operation). The weighing instrument controls battery status and displays a respective pictogram on the screen.

PEAK HOLD

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.

ANIMAL WEIGHING

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.

DATASHEET     

Maximum capacity [Max]3 kg
Minimum load20 g
Readability [d]1 g
Tare range-3 kg
Verification scale interval1 g
OIML ClassIII
DisplayLCD (backlit)
Protection classIP 68 construction, IP 68 cell, IP 68 (1h max)/69 indicator
Communication interfaceRS232
Power supply100 ÷ 240 V AC 50 / 60 Hz and battery
Operation time on batteries45 h (average time)
Operating temperature-10 ÷ +40 °C
Storage temperature-25 – +70 °C
Relative humidity10% ÷ 85% RH no condensation
ConstructionStal stainless steel AISI316
Weighing pan dimensions250×300 mm
Packaging dimensions580×320×360 mm
Net weight9 kg
Gross weight10.3 kg

ACCESSORIES

  • Granite Antivibration tables
  • Antivibrations Tables for Industrial Scales
  • Roller Table
  • Scales Editor
  • R-Lab
  • RAD – KEY
  • LabVIEW Driver
  • Receipt Printer
  • Moxa Uport 1110 Converter
  • RS232 – Ethernet Converter
  • RS 232 cables (scale – EPSON printer)
  • RS 232, RS 485 cables
  • Cigarrete lighter receptacle power supply cables
  • AP2-3 Current Loop Unit
  • RS 232 cables (terminal – terminal)
  • Displays

Our customer support team is here to answer your questions. Ask us anything!
//
Jawa Timur & Jawa Tengah
MARYOTO
Available
//
Jawa Barat
BAYU SOFYAN
Available
//
Jakarta, Banten, Sumatra & Sulawesi
ABDUL SYUKUR
Available
NOTICE
We use cookies to make your experience of our websites better.