Hi, ada yang dapat kami bantu?

Radwag PUE C32 Terminal

OVERVIEW

The Housing and the Display

The housing is made of durable ABS plastic. The indicator has been equipped with 5’’ colour display ensuring perfect readability, and 22-key membrane keypad featuring programmable function keys. The indicator offers customized menu, with this all your personal needs can be met which makes operation even more intuitive and simple.

Battery as an Optional Power Source

Use of the optional battery enables the PUE C32 indicator to operate even when there is either no or unstable power supply.

Communication Interfaces

Standard indicator has been equipped with RS 232, USB-A, USB-B, 4×IN, 4×OUT and Ethernet interfaces which facilitate both cooperation with peripherals such as printer or computer and data exchange using USB drives.
Learn that on your special request the PUE C32 can be equipped with wireless communication module allowing the indicator to connect with wireless networks.

Data Management

The data system of PUE C32 indicators is based on 7 databases, each featuring maximum records quantity:

  • Products – 15 000
  • Operators – 500
  • Formulations – 500
  • Packaging – 500
  • Customers – 500
  • Labels – 500
  • Universal variables – 100

Databases can be imported and exported via USB flash drives.

ALIBI Memory

ALIBI memory provides data safety and allows saving up to 500 thousand weighing records.This guaranties continuous storing of data over a long period of time.

Butuh Bantuan?

SKU: e66b48b16506 Kategori:

Informasi Produk

FUNCTIONS

LABELLING

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).

PERCENT WEIGHING

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.

PARTS COUNTING

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.

STATISTICS

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.

CHECKWEIGHING

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961

IR SENSORS

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.

GLP PROCEDURES

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.

REPLACEABLE UNIT

Replaceable units.

ALIBI MEMORY

“ALIBI” memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.

The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.

The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.

Measurements saved to balance memory cannot be deleted.

You can preview and print out the data saved to the ALIBI database.

DATASHEET

Maximum quantity of verification units 6000 e
Display 5″ graphic colour
Protection class IP 43
Communication interface 2×RS232, USB-A, USB-B, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®
Power supply 100 ÷ 240 V AC 50 / 60 Hz and battery
Operation time on batteries operation time up to 5 h
Maximum increase of signal 39 mV
Minimum volatge per verification unit 0.4 µV
Maximum voltage per verification unit 3.25 µV
Minimum load cell impedance 50 Ω
Maximum load cell impedance 1200 Ω
Load cell excitation voltage 5V DC
Connection of load cells 4 or 6 wires + shield
Operating temperature -0,25
 °C
Housing ABS plastic
Multiple range YES
Max number of platforms 1

COMPATIBLE WITH

  • Mild steel powder coated weighing platforms
  • Platforms in plastic casing
  • Mild steel powder coated weighing platforms
  • ALIBI Reader
  • E2R System
  • Label Editor R02
  • R.Barcode
  • R-LAB
  • RAD-KEY
  • RADWAG Connect
  • RADWAG Development Studio
  • labVIEW Driver
  • Label Printers
  • RS 232, RS 485 Cables
  • RS 232 cables (scale – ZEBRA Printer)
  • IN/OUT Cables
  • USB cables (scale – printer)
  • Keypad, external switches
  • Barcode Scanners
  • Stands, wall mounting kits and mounting brackets

We use cookies to make your experience of our websites better.